Reclaimed Water Gains Ground in Data Center Cooling

Reclaimed Water Gains Ground in Data Center Cooling

2026-10-27
Reclaimed Water Gains Ground in Data Center Cooling

International operators are expanding freshwater alternatives, bringing attention to the treatment systems that make reclaimed water suitable for specific cooling applications.

Reclaimed water is receiving greater attention as international data center operators seek alternatives to drinking water for cooling. Recent company announcements show that water reuse remains relevant alongside the development of cooling designs that reduce or avoid evaporation.

In June 2026, Google announced water stewardship commitments that included pursuing alternative supplies with utility partners. It cited its Douglas County, Georgia, campus as an example of using treated wastewater for cooling through cooperation with the local water and sewer authority. Google also said that watershed risk informs its choice of cooling approach. [1]

AWS described a planned expansion of recycled water use from 24 to more than 120 locations in the United States in November 2025. The company projected annual savings of more than 530 million gallons of drinking water. Those figures describe an announced expansion and expected savings, rather than confirmation that all locations have completed the transition. [2]

Cooling design determines the reuse opportunity

The opportunity for reclaimed water depends on the facility's actual cooling system. AWS explains that some of its facilities use evaporative cooling during hot periods and work with utilities to treat reclaimed water to appropriate standards for that purpose. [2]

For a project using cooling towers, reclaimed water may replace part or all of the potable makeup supply, subject to treatment and availability. A facility designed around dry heat rejection will have a different water balance. Project planning should therefore begin with the expected cooling demand and seasonal supply profile.

Treatment requirements begin with the source water

Reclaimed water varies in quality according to its source and upstream treatment. Pacific Northwest National Laboratory's review of cooling tower reuse systems explains that treatment requirements depend on both the alternative supply and the cooling equipment. Storage and distribution infrastructure are also part of the reuse system. [3]

Depending on the water analysis, a project may need filtration, chemical treatment or a more extensive treatment train. Source testing should establish the parameters that constrain use, rather than assume that an existing wastewater discharge specification is sufficient for cooling service. [3]

For water treatment suppliers, this makes a representative sample and the required outlet specification essential inputs. A process designed to remove suspended solids addresses a different problem from one designed to reduce hardness or dissolved salts.

Coagulation and flocculation have a defined role

Where suspended and colloidal material needs removal, coagulation and flocculation may form part of pretreatment before separation and filtration. EPA's water reuse guidance describes the role of coagulation and filtration in removing suspended material and supporting subsequent disinfection. The required process depends on the application and jurisdiction. [4]

Bluwat products such as polyaluminium chloride, PolyDADMAC, polyamine and polyacrylamide can be evaluated for defined clarification or sludge handling duties. Product choice, dosage and addition sequence require testing with the actual water and the proposed separation process.

These chemicals should be evaluated for the contaminants they are intended to remove. Conventional coagulation and flocculation do not provide desalination. Where dissolved salts or hardness constrain reuse, the process designer must assess suitable additional treatment. Upstream chemical residuals and carryover also need to meet downstream equipment requirements.

This pretreatment role is separate from coolant formulation. Suitability for raw water or reclaimed water treatment does not establish approval for direct dosing into a server cooling circuit.

Water reuse requires control of cooling tower chemistry

Replacing the makeup source does not eliminate the need to manage the recirculating water. As cooling tower water evaporates, dissolved minerals remain and become more concentrated. Blowdown removes part of that concentrated water to control the buildup. [5]

The US Department of Energy recommends using conductivity measurements and flow meters to manage cycles of concentration, with the operating target determined by water quality and the treatment program. Raising the concentration ratio can reduce blowdown, but the permissible limit depends on scaling and corrosion constraints. [5]

Microbial management is another consideration, particularly where cooling equipment produces mist. EPA's summary of California reuse requirements illustrates how treatment and disinfection obligations can vary with the cooling application and exposure route. Each international project needs to apply its own local requirements. [4]

Assessing a reuse project as a complete water system

For owners and engineering teams, the combined evidence supports assessing reclaimed water through a complete water balance and treatment plan. Available supply, storage, distribution, treatment needs and residual streams all affect feasibility. Pilot testing can help establish whether the selected process performs reliably with the available source. [3]

Potable water displacement, total water consumption and wastewater discharge should be reported separately. Substituting reclaimed water can reduce drinking water demand while evaporative cooling continues to consume water. Clear reporting helps operators explain what a reuse project has actually achieved.

About Bluwat Chemicals

Bluwat Chemicals supplies water treatment coagulants and flocculants for clarification, wastewater treatment and sludge dewatering. Its product range can be considered for suitable pretreatment duties within a data center water reuse project, subject to water analysis, laboratory evaluation and the requirements of the complete treatment system.

spandoek
Details van Oplossingen
Created with Pixso. Huis Created with Pixso. oplossingen Created with Pixso.

Reclaimed Water Gains Ground in Data Center Cooling

Reclaimed Water Gains Ground in Data Center Cooling

Reclaimed Water Gains Ground in Data Center Cooling

International operators are expanding freshwater alternatives, bringing attention to the treatment systems that make reclaimed water suitable for specific cooling applications.

Reclaimed water is receiving greater attention as international data center operators seek alternatives to drinking water for cooling. Recent company announcements show that water reuse remains relevant alongside the development of cooling designs that reduce or avoid evaporation.

In June 2026, Google announced water stewardship commitments that included pursuing alternative supplies with utility partners. It cited its Douglas County, Georgia, campus as an example of using treated wastewater for cooling through cooperation with the local water and sewer authority. Google also said that watershed risk informs its choice of cooling approach. [1]

AWS described a planned expansion of recycled water use from 24 to more than 120 locations in the United States in November 2025. The company projected annual savings of more than 530 million gallons of drinking water. Those figures describe an announced expansion and expected savings, rather than confirmation that all locations have completed the transition. [2]

Cooling design determines the reuse opportunity

The opportunity for reclaimed water depends on the facility's actual cooling system. AWS explains that some of its facilities use evaporative cooling during hot periods and work with utilities to treat reclaimed water to appropriate standards for that purpose. [2]

For a project using cooling towers, reclaimed water may replace part or all of the potable makeup supply, subject to treatment and availability. A facility designed around dry heat rejection will have a different water balance. Project planning should therefore begin with the expected cooling demand and seasonal supply profile.

Treatment requirements begin with the source water

Reclaimed water varies in quality according to its source and upstream treatment. Pacific Northwest National Laboratory's review of cooling tower reuse systems explains that treatment requirements depend on both the alternative supply and the cooling equipment. Storage and distribution infrastructure are also part of the reuse system. [3]

Depending on the water analysis, a project may need filtration, chemical treatment or a more extensive treatment train. Source testing should establish the parameters that constrain use, rather than assume that an existing wastewater discharge specification is sufficient for cooling service. [3]

For water treatment suppliers, this makes a representative sample and the required outlet specification essential inputs. A process designed to remove suspended solids addresses a different problem from one designed to reduce hardness or dissolved salts.

Coagulation and flocculation have a defined role

Where suspended and colloidal material needs removal, coagulation and flocculation may form part of pretreatment before separation and filtration. EPA's water reuse guidance describes the role of coagulation and filtration in removing suspended material and supporting subsequent disinfection. The required process depends on the application and jurisdiction. [4]

Bluwat products such as polyaluminium chloride, PolyDADMAC, polyamine and polyacrylamide can be evaluated for defined clarification or sludge handling duties. Product choice, dosage and addition sequence require testing with the actual water and the proposed separation process.

These chemicals should be evaluated for the contaminants they are intended to remove. Conventional coagulation and flocculation do not provide desalination. Where dissolved salts or hardness constrain reuse, the process designer must assess suitable additional treatment. Upstream chemical residuals and carryover also need to meet downstream equipment requirements.

This pretreatment role is separate from coolant formulation. Suitability for raw water or reclaimed water treatment does not establish approval for direct dosing into a server cooling circuit.

Water reuse requires control of cooling tower chemistry

Replacing the makeup source does not eliminate the need to manage the recirculating water. As cooling tower water evaporates, dissolved minerals remain and become more concentrated. Blowdown removes part of that concentrated water to control the buildup. [5]

The US Department of Energy recommends using conductivity measurements and flow meters to manage cycles of concentration, with the operating target determined by water quality and the treatment program. Raising the concentration ratio can reduce blowdown, but the permissible limit depends on scaling and corrosion constraints. [5]

Microbial management is another consideration, particularly where cooling equipment produces mist. EPA's summary of California reuse requirements illustrates how treatment and disinfection obligations can vary with the cooling application and exposure route. Each international project needs to apply its own local requirements. [4]

Assessing a reuse project as a complete water system

For owners and engineering teams, the combined evidence supports assessing reclaimed water through a complete water balance and treatment plan. Available supply, storage, distribution, treatment needs and residual streams all affect feasibility. Pilot testing can help establish whether the selected process performs reliably with the available source. [3]

Potable water displacement, total water consumption and wastewater discharge should be reported separately. Substituting reclaimed water can reduce drinking water demand while evaporative cooling continues to consume water. Clear reporting helps operators explain what a reuse project has actually achieved.

About Bluwat Chemicals

Bluwat Chemicals supplies water treatment coagulants and flocculants for clarification, wastewater treatment and sludge dewatering. Its product range can be considered for suitable pretreatment duties within a data center water reuse project, subject to water analysis, laboratory evaluation and the requirements of the complete treatment system.